Lighting panels manage the distribution, protection, and control of indoor and outdoor lighting circuits from a single point. Wrong circuit grouping or inadequate protection selection lets a single fault plunge a wide area into darkness. A correctly designed lighting panel directly affects both operational safety and energy efficiency.
Miratek addresses lighting panels together with the lighting design; circuit grouping, residual current protection, and emergency lighting segregation are settled at the design stage. Needs such as time relays, twilight sensors, or DALI- and KNX-based automation are integrated into the panel from the outset. Manufacturing, site installation, and commissioning are handled end to end.
Technical Scope Summary
| Voltage level | 230/400 V AC |
| Panel types | Indoor lighting distribution, outdoor area and perimeter lighting, emergency lighting panels |
| Control options | Time relay, astronomical relay, twilight sensor, DALI and KNX integration |
| Protection | Per-circuit breaker and residual current protection, surge arrester option for outdoor supplies |
| Application areas | Factories, warehouses, commercial buildings, area and road lighting |
| Delivery model | Turnkey including design, manufacturing, installation, and commissioning |
How We Work
Site survey and needs analysis
Lighting circuits, control scenarios, and the emergency lighting need are determined in place.
Design
Circuit grouping, protection selection, and the control architecture are settled on the design and submitted for approval.
Panel manufacturing
The panel is manufactured in the workshop; labelling and circuit diagram documentation are prepared.
Site installation
Panel installation and circuit connections are carried out without disturbing the existing operating routine.
Testing and commissioning
Residual current tests, control scenarios, and emergency lighting transfers are verified.
Scope of Work
- Design and manufacturing of indoor and outdoor lighting distribution panels
- Segregation of emergency lighting and exit guidance circuits within the panel
- Control integration based on astronomical relays, sensors, and automation
- Per-circuit protection and residual current coordination
- Supply panels for area and road lighting
- Installation, testing, and commissioning
Frequently Asked Questions
Does adding automation to a lighting panel save energy?
Yes. Outdoors, astronomical relay or sensor control eliminates unnecessary burn hours; indoors, DALI-based control cuts consumption through zoned switching and dimming. The gain is evaluated at the design stage against the facility's usage profile.
Can an emergency lighting circuit be added to our existing panel?
It can, if the panel's capacity and construction are suitable. The existing panel is examined during the survey, and the revision scope needed to protect and supply the emergency lighting circuits separately is reported. If it is unsuitable, a separate emergency lighting panel is recommended.
Quick Facts
- Category: Low Voltage Panel Services
- Turnkey delivery
- ISO 9001 quality assurance